This fieldbus connector links a PROFIBUS device to a PROFIBUS line.
The fieldbus connector has the following features:
For the first and last station on the bus, the switch must be set to “ON” (Terminating resistor activated, outgoing bus line disconnected) Switch setting to “OFF” for downstream bus stations (Terminating resistor deactivated)
", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-020000080000121e000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyODcxfGltYWdlL2pwZWd8YUdNeUwyaGxOaTh4TXpjNU5qWTBOREk1TURVNU1DOHhNakJmTURJd01EQXdNRGd3TURBd01USXhaVEF3TURFd01HSTJYMFJGTG1wd1p3fGVhZmQxZDRmZDQ4YWRkZDM5YTUyOTExOTAxODliNTU3MzQ1MTUxMDkwM2I5NDJkYTRhZTExNDZhYWIzZTBlZjY" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-020000080000121e000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNjc3fGltYWdlL2pwZWd8YURreUwyaGxaQzh4TXpjNU5qWTBOREE1TXprNE1pOHlNREJmTURJd01EQXdNRGd3TURBd01USXhaVEF3TURFd01HSTJYMFJGTG1wd1p3fDNiNTE1Y2Q2MGZmZTFjYzgzM2FjZWVmNDA3NmQ2ZjJmZmQ3NTJiYmU5Yzg2ZjM1NjRiYjNlM2M3ZWZhMTI0MzM" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-020000080000121e000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMDc0OXxpbWFnZS9qcGVnfGFEVXpMMmhsWlM4eE16YzVOalkwTkRBeU9EUTBOaTgwT0RCZk1ESXdNREF3TURnd01EQXdNVEl4WlRBd01ERXdNR0kyWDBSRkxtcHdad3w0YTBhMjFhZjFkZDllYWE5NTYwMzAyMjFhYjRlZmViZThlZjc2ZGY5MjM0MDIxYjNhODViMGI3MjgxOThjMTgw" } ], "infoArticle" : false, "name" : "Fieldbus Connector PROFIBUS; with D-sub male connector; 9-pole", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "productColor" : { "url" : "/medias/0003.png?context=bWFzdGVyfGltYWdlc3wyNTB8aW1hZ2UvcG5nfGFXMWhaMlZ6TDJobU5DOW9ObVV2TVRBME1qa3pPVFkzTnprd016Z3VjRzVufGZlNjQ3OWYxNThiOTc1MjgxOWY3NzM2MzA4ODlmM2IwNzM2MWRmMmVmMjZkYjQ5MTJhNDU4NzBmMDNhOWEyOGQ" }, "purchasable" : true, "sampleProduct" : false, "shortName" : "Fieldbus Connector PROFIBUS", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/plcs-controllers/fieldbus-connector-profibus/p/750-971", "uuid" : "wagoProductCatalog/Online/750-971" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Controller", "Industrial switches", "I/O Systems" ], "code" : "750-972", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "This fieldbus connector links a PROFIBUS device to a PROFIBUS line.
The fieldbus connector has the following features:
For the first and last station on the bus, the switch must be set to “ON” (Terminating resistor activated, outgoing bus line disconnected) Switch setting to “OFF” for downstream bus stations (Terminating resistor deactivated)
", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200000800000e7f000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wzMTE4fGltYWdlL2pwZWd8YURWakwyaGpOaTh4TWpVM01Ua3lPRFF5T0RVM05DOHhNakJmTURJd01EQXdNRGd3TURBd01HVTNaakF3TURFd01HSTJYMFJGTG1wd1p3fGQxNWVkZTg3ODA4OGMxZDQ5NDk3OWMyMWNmNjBlM2MzNWU5ODI5ZTQzYWZhNzJlN2ZkNGQ2ZWFmNDU4NWIzNzY" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200000800000e7f000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzUxfGltYWdlL2pwZWd8YURsbUwyaGlaaTh4TWpVM01Ua3lPREl6TVRrMk5pOHlNREJmTURJd01EQXdNRGd3TURBd01HVTNaakF3TURFd01HSTJYMFJGTG1wd1p3fDQxOTY3MDc4ZWM2YzdmZTIwZWQ5NDE4MDUyY2NlNDE3M2VlM2VmZDFhMTk2MjZjZWY0YTYzY2JkNmY4Yjg4MmI" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200000800000e7f000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMjA3MXxpbWFnZS9qcGVnfGFEaGxMMmhpWXk4eE1qVTNNVGt5T0RFMk5qUXpNQzgwT0RCZk1ESXdNREF3TURnd01EQXdNR1UzWmpBd01ERXdNR0kyWDBSRkxtcHdad3w3NDQwNTg5NTYwYzMwYjc3ZTE1NzgxYTMzMWJkZTdiYTViMjRkNDFkNWYxNmZjYmYyYTUyZjEyMGQzZThkY2M5" } ], "infoArticle" : false, "name" : "Fieldbus Connector PROFIBUS; with D-sub male connector; 9-pole", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "productColor" : { "url" : "/medias/0003.png?context=bWFzdGVyfGltYWdlc3wyNTB8aW1hZ2UvcG5nfGFXMWhaMlZ6TDJobU5DOW9ObVV2TVRBME1qa3pPVFkzTnprd016Z3VjRzVufGZlNjQ3OWYxNThiOTc1MjgxOWY3NzM2MzA4ODlmM2IwNzM2MWRmMmVmMjZkYjQ5MTJhNDU4NzBmMDNhOWEyOGQ" }, "purchasable" : true, "sampleProduct" : false, "shortName" : "Fieldbus Connector PROFIBUS", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/plcs-controllers/fieldbus-connector-profibus/p/750-972", "uuid" : "wagoProductCatalog/Online/750-972" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Controller" ], "code" : "758-970/000-300", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200000e0002924c000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMTExfGltYWdlL2pwZWd8YUdGaUwyaGhZUzh4TXprNU56VTRPVFkxT1RZM09DOHhNakJmTURJd01EQXdNR1V3TURBeU9USTBZekF3TURFd01HSTJYMFJGTG1wd1p3fDQ4OTY3MDBjNWY1NjM1MmI2ZDU2MjlhZjI3NmM0YjliNDc4YmNjMTY5YjI5ZGFhNTFjZjZmYWQwOGQ4ZTJiZjc" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200000e0002924c000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDA1fGltYWdlL2pwZWd8YUdJM0wyaGlaaTh4TXprNU56VTRPVEF3TkRNeE9DOHlNREJmTURJd01EQXdNR1V3TURBeU9USTBZekF3TURFd01HSTJYMFJGTG1wd1p3fGQwMzIxODAyY2QzMWUzNTI3YzE0ZGEzM2QzNDgzNDdiNmY2NjA2NWU2ZDNhOTBiMTZjNzkyZGQwYWMzODdlYTU" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200000e0002924c000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNTI1NXxpbWFnZS9qcGVnfGFHTmxMMmhsWlM4eE16azVOelU0T0RjME1qRTNOQzgwT0RCZk1ESXdNREF3TUdVd01EQXlPVEkwWXpBd01ERXdNR0kyWDBSRkxtcHdad3xmNTExYTViYjY1ZWEzMDVmZDBmOTk0NmI5NjU2NjliMDcxYTJkM2M3MTYxOGNhYjc1MWY0ODAyZTMxODhmNWMx" } ], "infoArticle" : false, "name" : "Connecting cable with SMA socket and SMA plug; Cable length 3 m; Cable type H155; GSM/ UMTS/ LTE/ Bluetooth®/ WLAN", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Connecting cable with SMA socket and SMA plug", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/plcs-controllers/connecting-cable-with-sma-socket-and-sma-plug/p/758-970_000-300", "uuid" : "wagoProductCatalog/Online/758-970/000-300" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Controller" ], "code" : "758-974", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "To get to know and test the WAGO Compact Controller 100, WAGO now offers the WAGO Compact Controller 100 Starter Kit.
This starter kit offers a quick, easy, cost-effective entry point into the world of WAGO controllers using the Compact Controller 100, CODESYS and the industrial IoT world (open automation).
Another advantage: The starter kit is ready to use – users can begin wiring immediately. Therefore, the starter kit is ideal for getting started with WAGO controllers and smaller automation solutions – regardless of the user’s level of expertise.
The benefits for you:
The LONWORKS® Controller is an expansion for the WAGO I/O System.
Application programming is IEC 61131-3 compliant.
The programmer can access all fieldbus and I/O data.
Features and applications:
In addition to the Neuron chip, the LONWORKS® Controller also has a host processor (40 MHz) that can be programmed via WAGO-I/O-PRO.
All available types of modules up to 248 digital or 124 analog input/output channels as well as modules with special functions can be addressed and handled using the program generated by WAGO-I/O-PRO.
The Neuron chip connection is made through IEC-61131-3 variables with special addresses. These can be imported via LNSTM-compliant PRIO LNS plug-in and assigned to a maximum of 52 network variables.
Any Standard Network Variable Type (SNVT) can be assigned to each of these network variables.
The PRIO LNS plug-in supports all available SNVTs from the LONMARK® SNVT Master List (1-31 bytes in length).
Network variables can be assigned to any SNVTs, ensuring the best possible interoperability with LONMARK-compliant products of other manufacturers.
", "familyName" : "Controller 750", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200000c0000fb50000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wzMTA1fGltYWdlL2pwZWd8YURSbUwyZ3laaTh4TXprNU56UTVOemd4TURrM05DOHhNakJmTURJd01EQXdNR013TURBd1ptSTFNREF3TURFd01HSTJYMFJGTG1wd1p3fGFlNzAwNWY0YzEyNGUwZjg3NGRkYWQ2M2U4NGRkNGEwYWRiODk1OTA0OWNhMWExZDk5ZTk1NDdmNzM1NmMwMGQ" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200000c0000fb50000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxOTM1fGltYWdlL2pwZWd8YURnNUwyZ3hOeTh4TXprNU56UTVOekV5TWpnME5pOHlNREJmTURJd01EQXdNR013TURBd1ptSTFNREF3TURFd01HSTJYMFJGTG1wd1p3fGY5NGQ3YmQ0Yjg2NzIyZWJmZGY1YzMzYjI1NWVmM2MyMjU3N2RkMGVlYjA5YWIyMmRhOWNjNzJlOWJjNjI2YTg" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200000c0000fb50000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMzQyMHxpbWFnZS9qcGVnfGFEQXhMMmd6WkM4eE16azVOelE1TmpjNU5URTJOaTgwT0RCZk1ESXdNREF3TUdNd01EQXdabUkxTURBd01ERXdNR0kyWDBSRkxtcHdad3xmNjIxOTAwZjQzOTJjNWZkMWQ4MjQzNWIwNjI2ZjBkZGYxZTU2YzcwNGY4ODNhNDJmMzk0YmYzM2RhMzFhMjUz" } ], "infoArticle" : false, "name" : "Controller LonWorks®", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "productColor" : { "url" : "/medias/0003.png?context=bWFzdGVyfGltYWdlc3wyNTB8aW1hZ2UvcG5nfGFXMWhaMlZ6TDJobU5DOW9ObVV2TVRBME1qa3pPVFkzTnprd016Z3VjRzVufGZlNjQ3OWYxNThiOTc1MjgxOWY3NzM2MzA4ODlmM2IwNzM2MWRmMmVmMjZkYjQ5MTJhNDU4NzBmMDNhOWEyOGQ" }, "purchasable" : false, "sampleProduct" : false, "shortName" : "Controller LonWorks®", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/plcs-controllers/controller-lonworks/p/750-819", "uuid" : "wagoProductCatalog/Online/750-819" }, { "announced" : false, "cancelled" : true, "categoryNames" : [ "Controller" ], "code" : "750-880/040-000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "The ETHERNET Controller can be used as a programmable controller within ETHERNET networks in conjunction with the WAGO I/O System.
The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 10/100 Mbit/s.
Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology, eliminating the need for additional network devices, such as switches or hubs. Both interfaces support autonegotiation and Auto-MDI(X).
The DIP switch configures the last byte of the IP address and may be used for IP address assignment.
The controller supports both MODBUS/TCP and EtherNet/IP for use in industrial environments. It also supports a wide variety of standard ETHERNET protocols for easy integration into IT environments (e.g., HTTP, BootP, DHCP, DNS, SNTP, SNMP, FTP).
For telecontrol applications, the 750-880/040-001 Controller supports the IEC 60870-5-101/-103-104, IEC 61850-7 and IEC 61400-25 communication protocols.
An integrated Webserver provides user configuration options, while displaying the controller's status information.
The IEC 61131-3 programmable controller is multitasking-capable and features a capacitor-backed RTC.
A data memory of 1 MB is available.
The 750-880 Controller is equipped with a removable memory card slot. A memory card can be used to transfer device parameters or files (e.g., boot files) from one controller to another. The memory card can be accessed via FTP and be used as an additional drive.
The device is ideal for operation in extreme environments thanks to:
The PFC200 Controller is a compact PLC for the modular WAGO I/O System. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.
Two ETHERNET interfaces and an integrated switch enable line topology wiring.
An integrated Webserver provides user configuration options, while displaying PFC200 status information.
Besides the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).
Programming per IEC 61131-3
The controllers are designed for the processing of WAGO applications. You can identify these controllers by a special version of the item number.
The application can be downloaded from the respective item on our website. Additional information can be obtained from the application documentation.
The controllers can also be used with their own applications as they offer all possibilities of the respective standard variant beyond the use of the WAGO application(s).
Programming per IEC 61131-3
The controllers are designed for the processing of WAGO applications. You can identify these controllers by a special version of the item number.
The application can be downloaded from the respective item on our website. Additional information can be obtained from the application documentation.
The controllers can also be used with their own applications as they offer all possibilities of the respective standard variant beyond the use of the WAGO application(s).
Programming per IEC 61131-3
The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 10/100 Mbit/s.
Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology, eliminating the need for additional network devices, such as switches or hubs. Both interfaces support autonegotiation and Auto-MDI(X).
The DIP switch configures the last byte of the IP address and may be used for IP address assignment.
This controller supports Modbus/TCP for use in industrial environments. It also supports a wide variety of standard ETHERNET protocols for easy integration into IT environments (e.g., HTTP(S), BootP, DHCP, DNS, SNTP, SNMP, (S)FTP).An integrated Webserver provides user configuration options, while displaying the controller's status information.
The IEC 61131-3 programmable controller is multitasking-capable and features a capacitor-backed RTC.
A data memory of 8 MB is available.
The controller is equipped with a removable memory card slot. A memory card can be used to transfer device parameters or files (e.g., boot files) from one controller to another. The memory card can be accessed via FTP and be used as an additional drive.
The device is ideal for operation in extreme environments thanks to:
The controller detects all connected I/O modules and creates a local process image. This process image may include a mixed arrangement of analog (word-by-word data transfer) and digital (bit-by-bit data transfer) modules.
Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology, eliminating the need for additional network devices, such as switches or hubs. Both interfaces support autonegotiation and Auto-MDI(X).
The DIP switch configures the last byte of the IP address and may be used for IP address assignment.
The controller is designed for fieldbus communication in Modbus® networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMP).An integrated Webserver provides user configuration options, while displaying the controller's status information.
The IEC 61131-3 programmable controller is multitasking-capable and features a capacitor-backed RTC.
", "familyName" : "Controller 750", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-02000034000254c1000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3w0NDA3fGltYWdlL2pwZWd8YURVM0wyZ3hOeTh4TXpnd016RTBOamsyT1RFeE9DOHhNakJmTURJd01EQXdNelF3TURBeU5UUmpNVEF3TURFd01HSTJYMFJGTG1wd1p3fDUxYjk4ODM4NjFkOWYxYmFiY2UzZDczMDI4ZTZjYjU3OTY2YzA0YjQ1Njc3NTk5OTlmMWVhZGZjYWFhMGQ5NTE" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-02000034000254c1000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNzk2fGltYWdlL2pwZWd8YURsaEwyZ3hNQzh4TXpnd016RTBOamMzTWpVeE1DOHlNREJmTURJd01EQXdNelF3TURBeU5UUmpNVEF3TURFd01HSTJYMFJGTG1wd1p3fDJlNjE1ZjJiYzAyYWE5ODUwZTMwZWZiY2IyMzU3YTRiZGNhMDcxOTA2NzkzN2EzMDhlZDMwNjRmMmMxZmIwMjk" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-02000034000254c1000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wzNjIwMXxpbWFnZS9qcGVnfGFHUTRMMmd3Wmk4eE16Z3dNekUwTmpjd05qazNOQzgwT0RCZk1ESXdNREF3TXpRd01EQXlOVFJqTVRBd01ERXdNR0kyWDBSRkxtcHdad3xmZjNkNDVjMjEyOGUwNGU3Y2ZhMmJjZDM1ZmY0ZDg0ZTBiMTg5Y2ZkMzZjZDc0MTUxZThlNTM0NjhkZGMyNTFl" } ], "infoArticle" : false, "name" : "Controller Modbus TCP; 4th generation; 2 x ETHERNET", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Controller Modbus TCP", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/plcs-controllers/controller-modbus-tcp/p/750-891", "uuid" : "wagoProductCatalog/Online/750-891" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Controller" ], "code" : "750-8210/040-000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "The PFC200 Controller is a compact PLC for the modular WAGO-I/O-SYSTEM. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.
Four ETHERNET interface and an integrated switch enable line aswell star topology wiring. An integrated Webserver provides user configuration options, while displaying PFC200 status information.
In addition to the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).
Advantages:
The device is ideal for operation in extreme environments thanks to:
The PFC200 Controller is a compact PLC for the modular WAGO I/O System. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty I/O modules found within the 750/753 Series.
Two ETHERNET interfaces and an integrated switch enable line topology wiring.
The integrated cellular modem enables a wireless connection to the Internet and includes a modem that can be used globally for engineering applications. The device includes a radio approval for EU countries and the countries listed in the eShop (other countries upon request). Other countries upon request.
An integrated Webserver provides user configuration options, while displaying PFC200 status information.
Besides standard machinery and equipment control, as well as building automation, typical applications for the PFC200 include decentralized data logging for the process industry.
Advantages:
The PFC200 Controller is a compact PLC for the modular WAGO I/O System. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.
Two ETHERNET interfaces and an integrated switch enable line topology wiring.
An integrated Webserver provides user configuration options, while displaying PFC200 status information.
Besides the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).
Programming per IEC 61131-3
The device is ideal for operation in extreme environments thanks to:
The 750‐830 BACnet/IP Controller connects the WAGO I/O System to the BACnet protocol
and supports the B‐BC BACnet device profile per DIN EN ISO 16484‐5.
The controller provides the three following functionalities:
Access to BACnet/IP networks is provided by the controller's RJ-45 interface.
The integrated RS-232 interface communicates with external devices. The controller can also be addressed as a MODBUS RTU slave via RS-232 interface.
The 750-830 Controller's application programming is IEC 61131-3 compliant.
It is capable of multitasking, has a battery-backed, real-time clock and is based on a 32-bit CPU.
HTML pages can be generated on an internal server for Web-based applications.
The CANopen Controller combines control functionality, I/O interface and fieldbus in one device.
Application programming is IEC 61131-3 compliant.
The programmer can access all fieldbus and I/O data.
Features and applications: