[{"term":"221","id":0,"type":"QUICKLINKS"},{"term":"Notas de aplicación","id":1,"type":"QUICKLINKS"},{"term":"Bibliotecas de automatización en edificios","id":2,"type":"QUICKLINKS"},{"term":"WAGO-I/O-PRO","id":3,"type":"QUICKLINKS"},{"term":"Edificio","id":4,"type":"QUICKLINKS"}]
{
"@context" : "http://schema.org/",
"@type" : "Product",
"name" : "Runtime; IEC60870 Master; M; Single License; Online activation",
"description" : "<b>Function:</b><br/>The parameters for communication per the IEC 60870 protocol can be set with a configurator that is integrated into the <b><i>e!</i></b><i>COCKPIT</i> Software. <br/>The configurator sets up IEC 60870 objects, while configuring data exchange to the PLC application or I/O modules. Importing and exporting functions in a CSV format allows configured data to be transmitted to other engineering tools.<br/>With this license, the protocols IEC 60870-5-101, -103 and -104 can be activated on the master. This permits the creation of gateways that convert one protocol into another, e.g., allowing protection devices to be read out via IEC 60870-5-103 and data to be transmitted to the network control system via IEC 60870-5-104.<br/><br/>IEC 60870-101/-104 information objects can be used to monitor the direction of single, double and step messages – bit patterns, counter values, as well as normalized, scaled and floating point measurement values can also be used. All information objects can be received with or without a time stamp. This also applies to information objects in the control direction.<br/><br/>The IEC 60870-5 master can support connections to up to 16 IEC 60870-5 slave devices.<br/><br/><b>Your Benefits:</b><br/><ul><li>Use the controller as a telecontrol master to read data from IEC-60870-5-101/-104 field devices or IEC-60870-5-103 protection devices (slaves) and process it locally in the controller. </li><li>Create a gateway application to use this master function to forward read data to a higher-level control system or cloud. This may require additional software licenses, such as the WAGO IEC 60870 Slave, DNP 3 Slave, SparcPlug or the WAGO Cloud.</li></ul><br/><br/><b>Use:</b><br/>Enter the license into <b><i>e!</i></b><i>COCKPIT</i>, assign it to a device and load both the license and project into the controller. No other steps are required.<br/><br/><b>Technical Data:</b><br/>See Section “Functionality of the WAGO Protocol Library according to IEC 60870-5-101, and -104” in Product Manual “Planning the IEC 60870 Protocol with the Telecontrol Configurator and <b><i>e!</i></b><i>COCKPIT</i>.”",
"mpn" : "2759-293/211-1000",
"sku" : "2759-293/211-1000",
"brand" : {
"@type":"Brand",
"name":"WAGO"
},
"manufacturer" : {
"@type":"Organization",
"name":"WAGO Kontakttechnik GmbH & Co. KG"
},
"image" : "https://www.wago.com/medias/200-5279193-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMTU5fGltYWdlL2pwZWd8YURCbUwyZzRPUzh4TXpjNU9EUXpPRFF6TmpnNU5DOHlNREJmTlRJM09URTVNMTlFUlM1cWNHY3w3NWJiMDY5ZjgyYzQyZGRlNzBkOTIyMjlhYWMzYjQyYjdmYjEwMzQ4MzU5ZTM4MmFiNjQ0NjFiNTkyYWRhY2Fm",
"gtin13" : "4066966109634",
"category" : "Software",
"url" : "https://www.wago.com/es/software/runtime/p/2759-293_211-1000"
}