{ "breadcrumbs" : [ ], "categoryCode" : "50017", "conditionalFacetGroups" : [ ], "currentQuery" : { "query" : { "autoSuggest" : false, "facets" : "", "ignoreResultType" : false, "sort" : "relevance", "text" : "*" }, "url" : "/c/software" }, "facetGroups" : [ { "displayName" : "Technical data", "name" : "TechnicalData", "priority" : 60 }, { "displayName" : "Approval data", "name" : "Approbations", "priority" : 25 }, { "displayName" : "Product area", "name" : "productarea", "priority" : 100 } ], "facets" : [ { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Produkttyp_7845", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "groupName" : "productarea", "lowBound" : false, "multiSelect" : true, "name" : "Product Type", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "Cables", "count" : 2, "name" : "Cables", "selected" : false }, { "code" : "Engineering software", "count" : 17, "name" : "Engineering software", "selected" : false }, { "code" : "Product set", "count" : 1, "name" : "Product set", "selected" : false }, { "code" : "Radio technology", "count" : 1, "name" : "Radio technology", "selected" : false }, { "code" : "Runtime software", "count" : 33, "name" : "Runtime software", "selected" : false }, { "code" : "Software Solution", "count" : 17, "name" : "Software Solution", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : -1, "bounded" : false, "category" : false, "code" : "facet_product_zulassungen", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTAND", "lowBound" : false, "multiSelect" : true, "name" : "Approvals", "priority" : 6000, "topValues" : [ { "code" : "30008", "count" : 1, "name" : "General approvals", "selected" : false }, { "code" : "30009", "count" : 1, "name" : "Declarations of conformity and manufacturer's declarations", "selected" : false }, { "code" : "30010", "count" : 0, "name" : "Approvals for marine applications", "selected" : false }, { "code" : "30011", "count" : 0, "name" : "Approvals for hazardous areas", "selected" : false }, { "code" : "30012", "count" : 0, "name" : "Approvals for radio applications", "selected" : false } ], "type" : "string", "values" : [ { "code" : "30009", "count" : 1, "name" : "Declarations of conformity and manufacturer's declarations", "selected" : false }, { "code" : "30008", "count" : 1, "name" : "General approvals", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Kommunikation_1712", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTAND", "groupName" : "TechnicalData", "lowBound" : false, "multiSelect" : true, "name" : "Fieldbus Protocols", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "BACnet/IP, requires an additional license", "count" : 1, "name" : "BACnet/IP, requires an additional license", "selected" : false }, { "code" : "EtherCAT® Master", "count" : 1, "name" : "EtherCAT® Master", "selected" : false }, { "code" : "EtherNet/IPTM Adapter (slave)", "count" : 1, "name" : "EtherNet/IPTM Adapter (slave)", "selected" : false }, { "code" : "EtherNet/IPTM Scanner", "count" : 1, "name" : "EtherNet/IPTM Scanner", "selected" : false }, { "code" : "MQTT", "count" : 1, "name" : "MQTT", "selected" : false }, { "code" : "Modbus (TCP, UDP)", "count" : 1, "name" : "Modbus (TCP, UDP)", "selected" : false }, { "code" : "Modbus RTU", "count" : 1, "name" : "Modbus RTU", "selected" : false }, { "code" : "OPC UA Server/Client", "count" : 1, "name" : "OPC UA Server/Client", "selected" : false }, { "code" : "RS-485 interface", "count" : 1, "name" : "RS-485 interface", "selected" : false }, { "code" : "Telecontrol protocols, requires an additional license", "count" : 1, "name" : "Telecontrol protocols, requires an additional license", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Konfiguration_ueber_7755", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "groupName" : "TechnicalData", "lowBound" : false, "multiSelect" : true, "name" : "Configuration", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "AT commands (e.g., via HyperTerminal)", "count" : 1, "name" : "AT commands (e.g., via HyperTerminal)", "selected" : false }, { "code" : "CODESYS V3.5", "count" : 1, "name" : "CODESYS V3.5", "selected" : false }, { "code" : "Ethernet Settings", "count" : 1, "name" : "Ethernet Settings", "selected" : false }, { "code" : "WAGO Solution Builder", "count" : 1, "name" : "WAGO Solution Builder", "selected" : false }, { "code" : "WAGOupload", "count" : 1, "name" : "WAGOupload", "selected" : false }, { "code" : "Web-Based Management", "count" : 1, "name" : "Web-Based Management", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Programmierung_7229", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "groupName" : "TechnicalData", "lowBound" : false, "multiSelect" : true, "name" : "Programming environment", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "CODESYS V3.5", "count" : 1, "name" : "CODESYS V3.5", "selected" : false }, { "code" : "Node RED", "count" : 1, "name" : "Node RED", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Protokolle_7243", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTAND", "groupName" : "TechnicalData", "lowBound" : false, "multiSelect" : true, "name" : "Protocols", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "DHCP", "count" : 1, "name" : "DHCP", "selected" : false }, { "code" : "DNS", "count" : 1, "name" : "DNS", "selected" : false }, { "code" : "FTP", "count" : 1, "name" : "FTP", "selected" : false }, { "code" : "FTPS", "count" : 1, "name" : "FTPS", "selected" : false }, { "code" : "HTTP", "count" : 1, "name" : "HTTP", "selected" : false }, { "code" : "HTTPS", "count" : 1, "name" : "HTTPS", "selected" : false }, { "code" : "NTP", "count" : 1, "name" : "NTP", "selected" : false }, { "code" : "SNMP", "count" : 1, "name" : "SNMP", "selected" : false }, { "code" : "SSH", "count" : 1, "name" : "SSH", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Serie", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "lowBound" : false, "multiSelect" : true, "name" : "Series", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "750", "count" : 3, "name" : "750", "selected" : false }, { "code" : "759", "count" : 6, "name" : "759", "selected" : false }, { "code" : "2759", "count" : 48, "name" : "2759", "selected" : false }, { "code" : "2762", "count" : 8, "name" : "2762", "selected" : false }, { "code" : "8101", "count" : 5, "name" : "8101", "selected" : false }, { "code" : "8103", "count" : 1, "name" : "8103", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 3, "bounded" : false, "category" : false, "code" : "facet_product_Visualisierung_7207", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "groupName" : "TechnicalData", "lowBound" : false, "multiSelect" : true, "name" : "Visualization", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "Web-Visu", "count" : 1, "name" : "Web-Visu", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : -1, "bounded" : false, "category" : false, "code" : "resultType", "discreteValues" : false, "excludedFromGuidance" : true, "facetType" : "MULTISELECTOR", "lowBound" : false, "multiSelect" : true, "name" : "resultType", "priority" : -9999, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "product", "count" : 71, "name" : "product", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Appro_30008", "discreteValues" : false, "excludedFromGuidance" : false, "facetType" : "MULTISELECTOR", "groupName" : "Approbations", "lowBound" : false, "multiSelect" : true, "name" : "General approvals", "priority" : 0, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "EAC", "count" : 1, "name" : "EAC", "selected" : false } ], "visible" : true }, { "amountItemsMinimized" : 5, "bounded" : false, "category" : false, "code" : "facet_product_Appro_30009", "discreteValues" : false, "excludedFromGuidance" : false, "facetType" : "MULTISELECTOR", "groupName" : "Approbations", "lowBound" : false, "multiSelect" : true, "name" : "Declarations of conformity and manufacturer's declarations", "priority" : 2, "topValues" : [ ], "type" : "string", "values" : [ { "code" : "EU-Declaration of Conformity", "count" : 1, "name" : "EU-Declaration of Conformity", "selected" : false } ], "visible" : true } ], "freeTextSearch" : "*", "guidanceFacet" : "facet_product_Appro_30008", "locationSearch" : false, "pagination" : { "currentPage" : 0, "pageSize" : 20, "sort" : "relevance", "totalPages" : 4, "totalResults" : 71 }, "results" : [ { "announced" : false, "cancelled" : false, "categoryNames" : [ "I/O Systems" ], "code" : "750-923", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " The WAGO USB Communication Cable connects a PC (notebook) to both the service interface of the 857 Series Signal Conditioners and the configuration interface of the WAGO I/O Fieldbus Couplers/Controllers. Notice! Using the WAGO 759-923 USB Communication Cable in combination with select programmable fieldbus controllers requires the specific firmware versions listed below: 750-841: Firmware Version 12 (or higher) 750-872/0020-0000: Firmware Version 2 (or higher) ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMTQ4fGltYWdlL2pwZWd8YURJMEwyZ3lNeTh4TWpVM01EY3lOelEwT0RZd05pOHhNakJmTURJd01EQXdNRGN3TURBd09UQXdZakF3TURFd01HSTJYMFJGTG1wd1p3fDlmYzM3NWY2NzkxZTFhODI3Y2I0MWYwNGU1YzIwZWY4MjI5ZWZiMzMxNjU2YmQzMTk1MDAyMTFiODE2YTY0Yzg" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNjE5fGltYWdlL2pwZWd8YURZMkwyZ3hZeTh4TWpVM01EY3lOekkxTVRrNU9DOHlNREJmTURJd01EQXdNRGN3TURBd09UQXdZakF3TURFd01HSTJYMFJGTG1wd1p3fDhlNWE2YzlmYTJiNTJiNjJjYzVhNDdmZDgyZjhjNGY1OWVhMGVlYTY3MWI5OWMzMmM2M2EyZTY2OGMxZGY5YmQ" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNTA1MHxpbWFnZS9qcGVnfGFEVTFMMmd4T1M4eE1qVTNNRGN5TnpFNE5qUTJNaTgwT0RCZk1ESXdNREF3TURjd01EQXdPVEF3WWpBd01ERXdNR0kyWDBSRkxtcHdad3xlMmUyNzVjNTA4NTg5YzgzNGQ2YTZlZjA3ZTZiMzI4NzM4Y2Q3ODUxN2E5YWFhYjJhZGRhMmM0MzZmNmIyYmIx" } ], "infoArticle" : false, "name" : "Configuration cable; USB connector; Length: 2.5 m", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "productColor" : { "url" : "/medias/0027.png?context=bWFzdGVyfGltYWdlc3wyNDh8aW1hZ2UvcG5nfGFXMWhaMlZ6TDJnelpDOW9NVE12TVRBME1qa3pPVGN3TURnME1UUXVjRzVufDMzYjVjOGYyZmNkYjk3NGRmNWMwYzM5NGMxODlhNmVlMzk4OWMxYjNhMWM2YWQ1N2Q1ODc1MTMzYTRiNjFlNGE" }, "purchasable" : true, "sampleProduct" : false, "shortName" : "Configuration cable", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/controllers-bus-couplers-i-o/configuration-cable/p/750-923", "uuid" : "wagoProductCatalog/Online/750-923" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "I/O Systems" ], "code" : "750-923/000-001", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " The WAGO USB Communication Cable connects a PC (notebook) to both the service interface of the 857 Series Signal Conditioners and the configuration interface of the WAGO I/O Fieldbus Couplers/Controllers. Notice! Using the WAGO 759-923 USB Communication Cable in combination with select programmable fieldbus controllers requires the specific firmware versions listed below: 750-841: Firmware Version 12 (or higher) 750-872/0020-0000: Firmware Version 2 (or higher) ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMTQ4fGltYWdlL2pwZWd8YURJMEwyZ3lNeTh4TWpVM01EY3lOelEwT0RZd05pOHhNakJmTURJd01EQXdNRGN3TURBd09UQXdZakF3TURFd01HSTJYMFJGTG1wd1p3fDlmYzM3NWY2NzkxZTFhODI3Y2I0MWYwNGU1YzIwZWY4MjI5ZWZiMzMxNjU2YmQzMTk1MDAyMTFiODE2YTY0Yzg" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNjE5fGltYWdlL2pwZWd8YURZMkwyZ3hZeTh4TWpVM01EY3lOekkxTVRrNU9DOHlNREJmTURJd01EQXdNRGN3TURBd09UQXdZakF3TURFd01HSTJYMFJGTG1wd1p3fDhlNWE2YzlmYTJiNTJiNjJjYzVhNDdmZDgyZjhjNGY1OWVhMGVlYTY3MWI5OWMzMmM2M2EyZTY2OGMxZGY5YmQ" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-020000070000900b000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNTA1MHxpbWFnZS9qcGVnfGFEVTFMMmd4T1M4eE1qVTNNRGN5TnpFNE5qUTJNaTgwT0RCZk1ESXdNREF3TURjd01EQXdPVEF3WWpBd01ERXdNR0kyWDBSRkxtcHdad3xlMmUyNzVjNTA4NTg5YzgzNGQ2YTZlZjA3ZTZiMzI4NzM4Y2Q3ODUxN2E5YWFhYjJhZGRhMmM0MzZmNmIyYmIx" } ], "infoArticle" : false, "name" : "Configuration cable; USB connector; Length: 5 m", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Configuration cable", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/controllers-bus-couplers-i-o/configuration-cable/p/750-923_000-001", "uuid" : "wagoProductCatalog/Online/750-923/000-001" }, { "announced" : false, "cancelDate" : "01.02.2024", "cancelled" : true, "categoryNames" : [ "I/O Systems" ], "code" : "750-921", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Bluetooth® Adapter in Connection with 750 Series The Bluetooth® Adapter wirelessly connects a notebook computer with Bluetooth® functionality to the service interface of the coupler/controller. It also provides an active connection to a programmable fieldbus controller. As a cable substitute, the Bluetooth® Adapter allows communication between two fieldbus controllers, as well as between fieldbus couplers/controllers via WAGO software tools (e.g., WAGO-I/O-CHECK, WAGO-I/O-PRO). Configurable coexistence properties ensure trouble-free operation in the presence of other radio systems. Bluetooth® Adapter in Connection with 857 SeriesThe Bluetooth® wirelessly connects a notebook computer with Bluetooth® functionality to the service interface of a configurable 857 Series Module. As a cable substitute, the Bluetooth® Adapter allows communication between Modules and WAGO software tool (WAGOframe) or configuration APP for Android-based end devices. If required, adapter configuration may be performed via AT commands. The adapter is supplied via both service interface and power supply of coupler/controller or Module. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-02000002000117f4000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDEyfGltYWdlL2pwZWd8YUdVMkwyaG1NeTh4TXpnd01ERXlNall4TXpjNU1DOHhNakJmTURJd01EQXdNREl3TURBeE1UZG1OREF3TURFd01HSTJYMFJGTG1wd1p3fDc0M2Y1MGQ1ZTA5NDJhNjc0ZTkxN2YyNjA0MjEzM2FkZjk5ZDJiOWU5ZTU5MWQ2YjVmZWM1NDEyMjUyZGJiZjI" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-02000002000117f4000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDAwfGltYWdlL2pwZWd8YUdJMkwyaG1ZUzh4TXpnd01ERXlNalF4TnpFNE1pOHlNREJmTURJd01EQXdNREl3TURBeE1UZG1OREF3TURFd01HSTJYMFJGTG1wd1p3fDc1MDE5OTI1MWEzNzE3NzI2N2JjNWVmZDVlMTRlOGJmOWIzODUxOTdiNmY4ODc4OTY1MTg2Nzg3YWExMmRkMWQ" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-02000002000117f4000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDM5MHxpbWFnZS9qcGVnfGFHSTFMMmhtWkM4eE16Z3dNREV5TWpNMU1UWTBOaTgwT0RCZk1ESXdNREF3TURJd01EQXhNVGRtTkRBd01ERXdNR0kyWDBSRkxtcHdad3xhZTk0N2YxN2RmMTVkM2E0M2ZlMzQ1MjZlMjcyMmQzYzQ1YzU4ZWY5ZWQ0YTgwZmYwMWU0ODVlOTc5MmNlMjZl" } ], "infoArticle" : false, "name" : "Bluetooth® Adapter", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "productColor" : { "url" : "/medias/0003.png?context=bWFzdGVyfGltYWdlc3wyNTB8aW1hZ2UvcG5nfGFXMWhaMlZ6TDJobU5DOW9ObVV2TVRBME1qa3pPVFkzTnprd016Z3VjRzVufGZlNjQ3OWYxNThiOTc1MjgxOWY3NzM2MzA4ODlmM2IwNzM2MWRmMmVmMjZkYjQ5MTJhNDU4NzBmMDNhOWEyOGQ" }, "purchasable" : false, "sampleProduct" : false, "shortName" : "Bluetooth® Adapter", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/controllers-bus-couplers-i-o/bluetooth-adapter/p/750-921", "uuid" : "wagoProductCatalog/Online/750-921" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-203/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " The WAGO Distributed Energy Resource Controller Library is a CODESYS 3.5 library with a control algorithm for active and reactive power in grid connected DER sites. \n \n The control algorithm for active and reactive power and corresponding setpoint specifications required by the grid operator can be adjusted during operation. The controller compares the specified setpoint values with the actual values measured at the DER connection point and provides the calculated correction variables to the connected DER. \n \n This library can be used on a wide verity of WAGO controllers and is programed with CODESYS 3.5 software. The application has been tested and is verified by a National Recognized Testing library to the IEEE 1547-2018 applicable clauses. \n \n The library can be used for a 30-day trial period at no cost, after which a license for the specific controller is required. The license can be purchased separately under Item Number 2759-203/211-1000. \n \n Functions: \n \n\t Q(PF): Fixed Power Factor specification\n\t \n\t\t Defined in IEEE1547-2018 Section 5.3.2 \n\t \n\t \n\t Q(Udb): Reactive Power control per voltage characteristic\n\t \n\t\t Defined in IEEE1547-2018 Section 5.3.3 \n\t \n\t \n\t Q(P): Reactive Power control per active power characteristic\n\t \n\t\t Defined in IEEE1547-2018 Section 5.3.4 \n\t \n\t \n\t Pfix, Qfix: Fixed active/reactive power specifications\n\t \n\t\t Defined in IEEE1547-2018 Section 5.3.5 \n\t \n\t \n\t P(V): Active Power control per voltage characteristic\n\t \n\t\t Defined in IEEE1547-2018 Section 5.4 \n\t \n\t \n\t P(f): Frequency-dependent active power regulation\n\t \n\t\t Defined in IEEE1547-2018 Section 6.5.2.7.2 \n\t \n\t \n \n", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2554437-DE.jpg?context=bWFzdGVyfGltYWdlc3wxOTYzfGltYWdlL2pwZWd8YUdNd0wyZzJPUzh4TXpnNU5ERTJOekk1T0RBM09DOHhNakJmTWpVMU5EUXpOMTlFUlM1cWNHY3wyYjRkOGJhNTU1YzMwMmFjZjc5YzBlYmMxMzRmNDI3NGRmYmExZGQwYzAyMjIwZWIyMzZjODk2OTliMTk2ZjVl" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2554437-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMjQ1fGltYWdlL2pwZWd8YURKa0wyZ3hOeTh4TXpnNU5ERTJOamt6TnpZek1DOHlNREJmTWpVMU5EUXpOMTlFUlM1cWNHY3w2MTFhYmYwYzlmMjI5ZGNlZjIxYzFmYTVkNjAyNTBkOWZkOTVlOTZhYjcxZDcxM2IxNGE1MDc4ZTU3MDJmMmIw" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2554437-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzIyNHxpbWFnZS9qcGVnfGFEWmxMMmd4TXk4eE16ZzVOREUyTmpnd05qVTFPQzgwT0RCZk1qVTFORFF6TjE5RVJTNXFjR2N8NDZiNzU5MTZmMThiNDNhOTM5OTk3YzBkZTFkMzdlODdiZDQ0YTZkMjc1MGY0Y2Q0OTk3Yjc3M2E0Y2YyMzk5ZA" } ], "infoArticle" : false, "name" : "Library Distributed Energy Resource Controller per 1547-2018; Single License", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Library Distributed Energy Resource Controller per 1547-2018", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/library-distributed-energy-resource-controller/p/2759-203_211-1000", "uuid" : "wagoProductCatalog/Online/2759-203/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-204/261-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "WAGO Lighting Management is a highly sophisticated solution for lighting control in large spaces, such as production facilities and warehouses. Using a combination of predefined hardware and user-friendly software, WAGO offers a lighting management system that facilitates the design and commissioning of new lighting systems while providing numerous additional advantages for their operation. The basic idea: WAGO Lighting Management is ready for the vastly different light requirements of warehouses and production facilities. For example, a production facility can be divided into virtual rooms in which the light can be flexibly adapted. Each virtual room receives signals from sensors and actuators in order to automatically set the appropriate light intensity. Virtual rooms allow quick, easy implementation of both conversions and remodeling via Web configuration. Compatible Controller: Controller PFC200; 2nd Generation; Item No.: 750-8212 ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNzY5fGltYWdlL2pwZWd8YUdWa0wyZ3lPQzh4TXpJME9UY3lNek16TkRZNE5pOHhNakJmTWpZeU9ETTFPVjlFUlM1cWNHY3wwNDk4M2Y3MGQxNTBlNDllNDExMWUwN2JiOGMyMmMwZWM4ZGZhMTRlNDMzYzVlMzhmMGNmNzdhZTgwM2U5NDNl" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODgyfGltYWdlL2pwZWd8YUdKa0wyZ3laaTh4TXpJME9UY3lNekV6T0RBM09DOHlNREJmTWpZeU9ETTFPVjlFUlM1cWNHY3xlMDMwZTlmZmNjMWFhODY3NWY4ZTU3MWEzOTI4NDg2MGQ5ZDY1NGFjMTgwOGVlODAyNDA3ZGE4MDQ0YjJmMjNj" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNDUzNHxpbWFnZS9qcGVnfGFHSmlMMmd6TWk4eE16STBPVGN5TXpBM01qVTBNaTgwT0RCZk1qWXlPRE0xT1Y5RVJTNXFjR2N8NTdlMWQ4M2U0YWZlNGQ1MmU4NTY4YmRiNjk5OTllZjVhMjQ2NzE0Y2RjODBmMWIzY2YzZDgyN2I2OTVjM2ZkOQ" } ], "infoArticle" : false, "name" : "Application Lighting Management; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Application Lighting Management", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/application-lighting-management/p/2759-204_261-1000", "uuid" : "wagoProductCatalog/Online/2759-204/261-1000" }, { "announced" : false, "cancelled" : true, "categoryNames" : [ "Software" ], "code" : "2759-101/1110-2002", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " WAGO Automation Software e!COCKPIT for faster machine and system startup: WAGO's new engineering software shortens development time for automation projects while impressing with a modern and clearly laid out user interface. At the software’s core is CODESYS V3 for simple and versatile creation of applications. Ensuring a project’s long-term viability through sustainable cost savings hinges on the user’s ability to quickly adapt to new software that offers a high degree of reusability. WAGO set out to fulfill these exact requirements by developing its own engineering software: e!COCKPIT. This integrated development environment supports every automation task, from hardware configuration, programming, simulation and visualization, to commissioning – all in one software package. Use the programming tool to handle all important automation tasks, and implement especially complex projects quickly and easily. Configuration and Parameterization The integrated e!COCKPIT configurators provide state-of-the-art operating tools and workspaces, such as: Graphical network topology: Complex relationships between network devices and their current states can be identified easily and intuitively. Drag & drop: Simplifies device interaction. Copy & paste: Individual devices or whole network branches can be duplicated quickly. Batch processing: Parameter values are set simultaneously for several devices. Programming e!COCKPIT offers multiple software development options: IEC 61131-3 PLC programming languages: Structured Text (ST), Ladder Diagram (LD), Function Block Diagram (FBD), Instruction List (IL), Sequential Function Chart (SFC), Continuous Function Chart (CFC) For flexibility, all programming languages can be combined with one another. Created programs can be easily debugged on the engineering PC via simulation. New paradigms such as object-oriented programming are included. Visualization Advanced user interfaces for machine operation and monitoring are standard. Today, HMI-based design is a critical factor that influences the purchase of an entire automation line. e!COCKPIT employs Drag & Drop to streamline the design of modern user interfaces. The integrated visualization editor provides: Access to IEC program variables Closed simulation of HMI and PLC programs on the engineering PC Guaranteed language independence via Unicode character set Current standards such as HTML 5 and CSS Diagnostics Being acutely aware of the automation network’s current status is vital for rapid fault localization and debugging – be it during development in the office or directly on the machine during commissioning. e!COCKPIT provides comprehensive diagnostic capabilities: Individual views, for example, always display the controllers’ status information both graphically and in tabular form. To keep the project on time, error messages are transmitted directly and clearly. The structured wiring test function systematically identifies wiring errors. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODc2fGltYWdlL2pwZWd8YUROaUwyZzBOQzh4TWpJMk5UTTNOekl6TkRrM05DOHhNakJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDE4ZGRhNWM3YjI4NjI3ZjI0ZGQzNTZmYTdkNTY2Y2JlNDhmYzNiY2E3ODc3MTZmNDFkMDJhMTAyZDc0MTg0MzE" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDU3fGltYWdlL2pwZWd8YURCaUwyZzBZaTh4TWpJMk5UTTNOekF6T0RNMk5pOHlNREJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDgxY2YxMzU3NTBmMGRiYTE5YjdmYmMzOTRhNjRhMDlhMWYzODc3YThhZmRjODlmZDYwMzVjZGU2MDFhMTA2YWM" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxOTQxOHxpbWFnZS9qcGVnfGFHSTFMMmc1TlM4eE1qSTJOVE0zTmprM01qZ3pNQzgwT0RCZk1ESXdNREF3TVdNd01EQXlaakJtTXpBd01ERXdNR0kyWDBSRkxtcHdad3xjYmQyNGFkNTE0MmMyMjliMjcxY2VhNjBjMzEwYzUwZmUzY2VkODU0YThiYWExNmJjOTlkMjJkZjk3MTI2MzNk" } ], "infoArticle" : false, "name" : "e!COCKPIT software; license (single workstation)", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : false, "sampleProduct" : false, "shortName" : "e!COCKPIT software", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/e-cockpit-software/p/2759-101_1110-2002", "uuid" : "wagoProductCatalog/Online/2759-101/1110-2002" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-283/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Function: “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies communication between products from different manufacturers. The PFC200 Controller (2nd generation) can be operated as a BACnet building controller and supports the B-BC device profile with all major BACnet objects and interoperability building blocks (BIBBs). The device communicates via BACnet/IP and offers the functionality of a BACnet Client and BACnet Server. To use BACnet/IP, it is necessary to equip the device with a license. The BACnet network is configured using the WAGO BACnet Configurator and the Engineering Software. Benefits: Use the device as a BACnet Building Controller (B-BC) Control and detect distributed I/O signals from WAGO BACnet/IP Couplers via BACnet Fieldbus Protocol Data exchange with other BACnet Devices as a BACnet Client or Server Use: The license is registered in WAGO Upload and loaded onto a device. No other installation steps are required. Technical Data: See “Protocol Implementation Conformance Statement” (PICS) Compatible Controllers: 750-8210 PFC200; G2; 4ETH 750-8211 PFC200; G2; 2ETH 2SFP 750-8212 PFC200; G2; 2ETH RS 750-8213 PFC200; G2; 2ETH CAN 750-8216 PFC200; G2; 2ETH RS CAN DPS 750-8217 PFC200; G2; 2ETH RS; 4G ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzk1fGltYWdlL2pwZWd8YUdaaUwyaGlPUzh4TXpJME9UVTNOell4TlRNNU1DOHhNakJmTWpRNU5UWTFNVjlFUlM1cWNHY3w1YzIzNGJiOTJhZTA2N2FlOGRkODQyYzNiZjczODFlNDUyNmY1MjU2YzdkZDNkYzg0ZDkxYzZhMTA0ODk5NWU5" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMTk2fGltYWdlL2pwZWd8YUdOakwyaGpNQzh4TXpJME9UVTNOelF4T0RjNE1pOHlNREJmTWpRNU5UWTFNVjlFUlM1cWNHY3w2ZDEwY2VhZjU2NWVlZDVmNGMzOGZmODhkZDYzNWE1YmNhMmJkMWVjMWExOWM1MThjNmJmMWJlOWMwMGVmZmQ3" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODEzNHxpbWFnZS9qcGVnfGFHTmhMMmhqTXk4eE16STBPVFUzTnpNMU16STBOaTgwT0RCZk1qUTVOVFkxTVY5RVJTNXFjR2N8NDY4OWYxNTkxYzc2ZDVhODUxZDNmMGM1MGQ0OGQ3NmUyMDQyMTgyZjk0N2ExNGMwNmQ5YzM2ZDNjZjMwZTY0Yg" } ], "infoArticle" : false, "name" : "Runtime; BACnet; 300; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Runtime", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/runtime/p/2759-283_211-1000", "uuid" : "wagoProductCatalog/Online/2759-283/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-290/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Function: Communication according to the IEC 61850 Protocol can be conveniently parameterized with a configurator integrated into the e!COCKPIT Software. The configurator sets up IEC 60870 objects while configuring data exchange to the PLC application or I/O modules. Import and export functions in CSV format allow configured data to be transmitted to other engineering tools. With this license, the IEC 60870-5-101 and -104 Protocols on the slave. This permits the creation of gateways that convert one protocol into another, e.g., allowing protection devices to be read out via Modbus and data to be transmitted to the network control system via IEC 60870-5-104. The time on the telecontrol substation (slave) can be directly synchronized via either the IEC 60870 Protocol with object 103 or via (S)NTP. IEC 60870-5-101/-104 Information Objects can be used to monitor the direction of single, double and step messages – bit patterns, counter values, as well as normalized, scaled and floating-point measurement values can also be used. All information objects can be transmitted with or without a time stamp. This also applies to information objects in the control direction. An IEC 60870-5-104 Slave can simultaneously maintain up to four connections to the control system (master). Your Benefits: Use the PFC200 Controller as a telecontrol substation (slave) on an IEC 60870-5-101/-104 control system (master). Create a gateway application to transfer data from Modbus protection devices to an IEC 60870-5-101/-104 control system. Uses: Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the controller. No other installation steps are required. Technical Data: See Section “Functionality of the WAGO Protocol Library according to IEC 60870-5-101, and -104” in Product Manual “Configuring the IEC 60870 Protocol.” ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-3061721-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODE5fGltYWdlL2pwZWd8YURjekwyaGpZUzh4TXpnd01EazVNRGt6TXpBeU1pOHhNakJmTXpBMk1UY3lNVjlFUlM1cWNHY3wzNWJmNTVhZmU2NDMzZGQzMmNkNTNlZDY1NDQ2YmNkY2RkODI5MjQyOTZiYTk4MGRlNDQ5NGI5YjE5NTMxMjMx" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-3061721-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMzA4fGltYWdlL2pwZWd8YURRekwyaGtNUzh4TXpnd01EazVNRGN6TmpReE5DOHlNREJmTXpBMk1UY3lNVjlFUlM1cWNHY3wzN2E4NTgxMmNjNGMyYTgxNmY5NzdmMzUyMWUxNzFjNThkMWM5NWZhNDljZjc2MGY3NDk4NTY2YTQ4N2U4NmIy" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-3061721-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDg0NHxpbWFnZS9qcGVnfGFEUXhMMmhrTkM4eE16Z3dNRGs1TURZM01EZzNPQzgwT0RCZk16QTJNVGN5TVY5RVJTNXFjR2N8NzBiNGY5YWExMWI3ZDkyM2EyYmU1NWIxNDlmZWM0ZmU5YjIyN2I1MDQ5MTQwYzFmOTU5ZTUyNmFjOTViMDg1OQ" } ], "infoArticle" : false, "name" : "Runtime; IEC60870 Slave; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Runtime", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/runtime/p/2759-290_211-1000", "uuid" : "wagoProductCatalog/Online/2759-290/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-206/261-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " With WAGO's Energy Data Management solution, you can record and visualize your measurement data for different media and influencing variables (as well as the key figures calculated from it) in no time. Continuous acquisition and monitoring provide the basis for resource-efficient energy usage – the environment will thank you, and your operating costs will be minimized. As an added bonus, conformity with DIN EN 50001 for energy evaluation is part of the package. WAGO Energy Data Management consists of Web-based application software combined with a modular control system. It records measurement data for different media along with influencing variables for energy monitoring – all are processed for additional analysis, archiving and reporting. The software automatically detects different signals from the connected meters and sensors, making them available to additional energy analysis tools via simple parameter settings. This insight guides you in optimizing energy consumption in your building or production facility – either locally or across the globe. Compatible Controllers/Touch Panels: PFC200 G2; PFC200 Controller as basic unit, available in different configurations: 750-821x PFC200 G2 XTR; Alternative: PFC200 for extreme environments: 750-821x/040-000 Touch Panel 600 Standard Line; PIO3; 762-4304/8000-0002 Touch Panel 600 Advanced Line; PIO3; 762-5304/8000-0002 ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2475283-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMzk5fGltYWdlL2pwZWd8YUdZM0wyaGxOQzh4TXpJME9UWTBOVEUxTURJek9DOHhNakJmTWpRM05USTRNMTlFUlM1cWNHY3wwM2IxYzZhY2ExNzI4MjQ0MGQ1MjY0NTk4MDNhMjAyYzcyYTAxZDkxNmNiZTZjNjBhNDI4ZjFkMzYwZWNhYzky" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2475283-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDY5fGltYWdlL2pwZWd8YURoakwyaGpZeTh4TXpJME9UWTBORGsxTXpZek1DOHlNREJmTWpRM05USTRNMTlFUlM1cWNHY3xmYjc1NzI2MGYyYzRkYTBmZTEzYmM2MDIyZjkyZjM0ZDQ3M2RiYTRhZWU1YjU4OWMxNjc3YTk0NjJiNmViYTZh" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2475283-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMjI5OHxpbWFnZS9qcGVnfGFEZGlMMmhqT1M4eE16STBPVFkwTkRnNE9EQTVOQzgwT0RCZk1qUTNOVEk0TTE5RVJTNXFjR2N8ZTQ2MDQ3NTk2NDRiNzVjNmRmMmEyMTAwYTIyNmVmYTY5MjYzOWE1MzA4Y2ZkZjU4MjZlZmM0OGYyNzQwMzVkOQ" } ], "infoArticle" : false, "name" : "Application Energy Data Management; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Application Energy Data Management", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/application-energy-data-management/p/2759-206_261-1000", "uuid" : "wagoProductCatalog/Online/2759-206/261-1000" }, { "announced" : false, "cancelled" : true, "categoryNames" : [ "Software" ], "code" : "2759-101/1110-2005", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " WAGO Automation Software e!COCKPIT for faster machine and system startup: WAGO's new engineering software shortens development time for automation projects while impressing with a modern and clearly laid out user interface. At the software’s core is CODESYS V3 for simple and versatile creation of applications. Ensuring a project’s long-term viability through sustainable cost savings hinges on the user’s ability to quickly adapt to new software that offers a high degree of reusability. WAGO set out to fulfill these exact requirements by developing its own engineering software: e!COCKPIT. This integrated development environment supports every automation task, from hardware configuration, programming, simulation and visualization, to commissioning – all in one software package. Use the programming tool to handle all important automation tasks, and implement especially complex projects quickly and easily. Configuration and Parameterization The integrated e!COCKPIT configurators provide state-of-the-art operating tools and workspaces, such as: Graphical network topology: Complex relationships between network devices and their current states can be identified easily and intuitively. Drag & drop: Simplifies device interaction. Copy & paste: Individual devices or whole network branches can be duplicated quickly. Batch processing: Parameter values are set simultaneously for several devices. Programming e!COCKPIT offers multiple software development options: IEC 61131-3 PLC programming languages: Structured Text (ST), Ladder Diagram (LD), Function Block Diagram (FBD), Instruction List (IL), Sequential Function Chart (SFC), Continuous Function Chart (CFC) For flexibility, all programming languages can be combined with one another. Created programs can be easily debugged on the engineering PC via simulation. New paradigms such as object-oriented programming are included. Visualization Advanced user interfaces for machine operation and monitoring are standard. Today, HMI-based design is a critical factor that influences the purchase of an entire automation line. e!COCKPIT employs Drag & Drop to streamline the design of modern user interfaces. The integrated visualization editor provides: Access to IEC program variables Closed simulation of HMI and PLC programs on the engineering PC Guaranteed language independence via Unicode character set Current standards such as HTML 5 and CSS Diagnostics Being acutely aware of the automation network’s current status is vital for rapid fault localization and debugging – be it during development in the office or directly on the machine during commissioning. e!COCKPIT provides comprehensive diagnostic capabilities: Individual views, for example, always display the controllers’ status information both graphically and in tabular form. To keep the project on time, error messages are transmitted directly and clearly. The structured wiring test function systematically identifies wiring errors. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODc2fGltYWdlL2pwZWd8YUROaUwyZzBOQzh4TWpJMk5UTTNOekl6TkRrM05DOHhNakJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDE4ZGRhNWM3YjI4NjI3ZjI0ZGQzNTZmYTdkNTY2Y2JlNDhmYzNiY2E3ODc3MTZmNDFkMDJhMTAyZDc0MTg0MzE" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDU3fGltYWdlL2pwZWd8YURCaUwyZzBZaTh4TWpJMk5UTTNOekF6T0RNMk5pOHlNREJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDgxY2YxMzU3NTBmMGRiYTE5YjdmYmMzOTRhNjRhMDlhMWYzODc3YThhZmRjODlmZDYwMzVjZGU2MDFhMTA2YWM" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxOTQxOHxpbWFnZS9qcGVnfGFHSTFMMmc1TlM4eE1qSTJOVE0zTmprM01qZ3pNQzgwT0RCZk1ESXdNREF3TVdNd01EQXlaakJtTXpBd01ERXdNR0kyWDBSRkxtcHdad3xjYmQyNGFkNTE0MmMyMjliMjcxY2VhNjBjMzEwYzUwZmUzY2VkODU0YThiYWExNmJjOTlkMjJkZjk3MTI2MzNk" } ], "infoArticle" : false, "name" : "e!COCKPIT software; license (5 users)", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : false, "sampleProduct" : false, "shortName" : "e!COCKPIT software", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/e-cockpit-software/p/2759-101_1110-2005", "uuid" : "wagoProductCatalog/Online/2759-101/1110-2005" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-2103/271-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "WAGO Visualization Lighting Management provides an optional independent user interface for operating and monitoring WAGO Lighting Management (2759-0204/0261-1000). Whether on a desktop PC, touch panel, tablet or smartphone, the entire lighting system can be operated clearly and conveniently during ongoing operation via a modern HTML 5 web user interface. Through the visualization of operating data, the user is informed at all times about the current operating status of the entire lighting system and can intervene manually if necessary. Simultaneously accessing several lighting management controllers from the visualization is also possible. Depending on the number of controllers to be operated, three different license types are available. The visualization can be easily adapted to individual requirements. In addition to language and color settings, HMI devices, users, rooms and custom profiles in particular can be created and managed. Profiles make it possible to associate an individual user interface with each HMI device or user. Visualization – S; 1 controller; Item No.: 2759-2101/271-1000 Visualization – M; up to 3 controllers; Item No.: 2759-2102/271-1000 Visualization – L; up to 10 controllers; Item No.: 2759-2103/271-1000 Compatible Controllers/Touch Panels: Controller PFC200; 2nd Generation; Item No.: 750-8212 Touch Panel 600 Advanced Line; PIO3; Alternative: Touch Panel with capacitive touchscreen as basic unit: 762-53xx/8000-0002 ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNzY5fGltYWdlL2pwZWd8YUdWa0wyZ3lPQzh4TXpJME9UY3lNek16TkRZNE5pOHhNakJmTWpZeU9ETTFPVjlFUlM1cWNHY3wwNDk4M2Y3MGQxNTBlNDllNDExMWUwN2JiOGMyMmMwZWM4ZGZhMTRlNDMzYzVlMzhmMGNmNzdhZTgwM2U5NDNl" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODgyfGltYWdlL2pwZWd8YUdKa0wyZ3laaTh4TXpJME9UY3lNekV6T0RBM09DOHlNREJmTWpZeU9ETTFPVjlFUlM1cWNHY3xlMDMwZTlmZmNjMWFhODY3NWY4ZTU3MWEzOTI4NDg2MGQ5ZDY1NGFjMTgwOGVlODAyNDA3ZGE4MDQ0YjJmMjNj" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNDUzNHxpbWFnZS9qcGVnfGFHSmlMMmd6TWk4eE16STBPVGN5TXpBM01qVTBNaTgwT0RCZk1qWXlPRE0xT1Y5RVJTNXFjR2N8NTdlMWQ4M2U0YWZlNGQ1MmU4NTY4YmRiNjk5OTllZjVhMjQ2NzE0Y2RjODBmMWIzY2YzZDgyN2I2OTVjM2ZkOQ" } ], "infoArticle" : false, "name" : "Visualization Lighting Management; L; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Visualization Lighting Management", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/visualization-lighting-management/p/2759-2103_271-1000", "uuid" : "wagoProductCatalog/Online/2759-2103/271-1000" }, { "announced" : false, "cancelDate" : "01.06.2024", "cancelled" : true, "categoryNames" : [ "Software" ], "code" : "759-333/000-923", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "WAGO-I/O-PRO is a programming and visualization tool for control programs, allowing users to develop PLC applications for the programmable fieldbus controllers of the WAGO I/O System 750. WAGO-I/O-PRO runs in compliance with the IEC 61131-3 standard, which specifies the requirements for a programming system. The IL, SFC, LD, FBD and ST programming languages are supported. The optimal programming language can be chosen for each application. With extensive programming functions, the software readily meets the increasing demands on control program development, e.g., reusability and modularization. Efficiently translate between programming languages Automatic variable declaration Library management Integrated test and diagnostic functions also streamline and accelerate the steps for implementing PLC projects. Program code with online status indicator Offline simulation Integrated process visualization Record and graphically display project variables WAGO-I/O-PRO also offers the option of programming your existing products from other manufacturers within the CODESYS automation alliance in addition to WAGO's standard programmable CODESYS automation alliance products.", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-020000090000afec000200b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wzMTgyfGltYWdlL2pwZWd8YURVNUwyZ3daaTh4TWpJMk5UVXpOVGc1TnpZek1DOHhNakJmTURJd01EQXdNRGt3TURBd1lXWmxZekF3TURJd01HSTJYMFJGTG1wd1p3fDcwYTZjM2ZkZDBjOGUwOGJkZWU0NDNkMDg5NzVlMDk2YWIxZGVkZDBkNTU2MTk1NzBhZDZlZWFmOTU3N2U3ZjQ" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-020000090000afec000200b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMTIyfGltYWdlL2pwZWd8YUdWakwyZ3dZUzh4TWpJMk5UVXpOVGN3TVRBeU1pOHlNREJmTURJd01EQXdNRGt3TURBd1lXWmxZekF3TURJd01HSTJYMFJGTG1wd1p3fGZmM2ZhOWUxYjY5MWNiNzZjZjk1MzY3Y2JmNDU2MmQwN2U1MDExOTJjM2Q5ZTMzM2Q2YjEzNWRiMjVlZjc1ZDc" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-020000090000afec000200b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wzNzc2MHxpbWFnZS9qcGVnfGFHUmlMMmd3Tnk4eE1qSTJOVFV6TlRZek5UUTROaTgwT0RCZk1ESXdNREF3TURrd01EQXdZV1psWXpBd01ESXdNR0kyWDBSRkxtcHdad3w5OGFmZTcwMTBmZjFmMmExNmNmODgyNWEyY2E2MTBlZGRlYWE1OTEyM2FjZjRjNzMzM2Q0ZDE1YjlhZGI1YzQy" } ], "infoArticle" : false, "name" : "WAGO-I/O-PRO; USB-Set", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : false, "sampleProduct" : false, "shortName" : "WAGO-I/O-PRO", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/wago-i-o-pro/p/759-333_000-923", "uuid" : "wagoProductCatalog/Online/759-333/000-923" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-2120/261-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "WAGO Application Building Control is a pre-programmed software solution for building automation applications. The application is ideal for virtually all building automation functions, such as lighting control, HVAC control, and energy data management. Despite pre-programming, it is possible to define almost any data points that can be linked together, put into dependency with each other or provided with control and regulating functions. The application has an integrated dashboard for advanced visualization options. Commissioning is performed through a configuration interface, following the design principle of “configuration instead of programming.” Advantages: Easy configuration, commissioning and operation without programming knowledge Highly versatile High flexibility and scalability for adapting to different needs Integrated monitoring, alarming for limit violation and status monitoring Optional connection to “WAGO Cloud Building Operation and Control” cloud solution for access to all of the data from anywhere in the world Benefits: High cost efficiency and profitability thanks to quick and easy commissioning User-friendly and intuitive visualization and operation High functional safety and reliability thanks to pre-programmed and tested functional units ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-7572099-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMTY0fGltYWdlL2pwZWd8YURjNEwyZ3hZUzh4TXpJME56Z3hOemswTVRBeU1pOHhNakJmTnpVM01qQTVPVjlFUlM1cWNHY3xmZTRhMzI1NGJjNmZmOWM0YmZjY2VjODNkMDFmYjk1MjFiOGFkMjYzZjExMTY4NDU2YzdiNzJjYTZlYjMyZTNl" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-7572099-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDgwfGltYWdlL2pwZWd8YUdJeEwyZ3hPUzh4TWpjME1UQXlOakF5TVRRd05pOHlNREJmTnpVM01qQTVPVjlFUlM1cWNHY3w5NTVmODE1MGE2NDY4Zjc5NTU4MzA5YmVkYzU5MzMxOWE0OTg4YjllODk5NjMxNWVmMzYwMTEyZjdlYzJiNTJl" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-7572099-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzAzOHxpbWFnZS9qcGVnfGFHTmhMMmd6TkM4eE1qYzBNVEF5TlRneU5EYzVPQzgwT0RCZk56VTNNakE1T1Y5RVJTNXFjR2N8Y2FiOTk4Y2FlMzU1NGIxMGZjYTFjZTc5OTgyMDFkMmIyMDNlYjMwYWJmYWI1MTZiZTdiODU1ZTYzM2Y1YzE4Nw" } ], "infoArticle" : false, "name" : "Application Building Control; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Application Building Control", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/application-building-control/p/2759-2120_261-1000", "uuid" : "wagoProductCatalog/Online/2759-2120/261-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "759-302/000-923", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " WAGO-I/O-CHECK is an easy-to-use Windows application for operating and displaying a WAGO I/O System 750's node without connecting to a fieldbus system. The software reads the configuration from the node and displays it graphically on the screen. This graphic can be printed together with a configuration list as documentation. With WAGO-I/O-CHECK, it is possible to display and specify the process data of the I/O modules. The field wiring, including all sensors and actuators, can thus be checked before startup. For some types of interface, Pt100 and thermocouple modules, application-specific settings can be made, such as the baud rate or sensor types. The coupler must be connected to a free serial or USB port of the PC using the communication cable supplied in the set with the system to enable communication between WAGO‐I/O‐CHECK and the node. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-02000003000021aa000300b6-DE.jpg?context=bWFzdGVyfGltYWdlc3w0MTU1fGltYWdlL2pwZWd8YURJNEwyZ3lPUzh4TWpVM01qSXlOelF3TXpnd05pOHhNakJmTURJd01EQXdNRE13TURBd01qRmhZVEF3TURNd01HSTJYMFJGTG1wd1p3fGIwMGY2NGZkZjljM2ViZGRhMWQzYTNiYWU2MDk1NmMyYWRiM2E3Yzk5ZDQxZmY2YjliNTI5YTg4MDI2ODk3NzQ" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-02000003000021aa000300b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wyMzQwfGltYWdlL2pwZWd8YURVNEwyZ3lNaTh4TWpVM01qSXlOekl3TnpFNU9DOHlNREJmTURJd01EQXdNRE13TURBd01qRmhZVEF3TURNd01HSTJYMFJGTG1wd1p3fDFjNzhmZThlYzM4YmRjZDE1ODQ1ZmQyYjQ5ZjQ4Y2YyMzU5ODgwY2IwNjZkMzQ3NzA3ZTZmNjYzNmNlZmI2ZDY" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-02000003000021aa000300b6-DE.jpg?context=bWFzdGVyfGltYWdlc3w0Njg0MXxpbWFnZS9qcGVnfGFEVmhMMmd4Wmk4eE1qVTNNakl5TnpFME1UWTJNaTgwT0RCZk1ESXdNREF3TURNd01EQXdNakZoWVRBd01ETXdNR0kyWDBSRkxtcHdad3xmOGMzM2UyNmMyMzE3ZTA0NTFhMzJlYmEyYjFiYThiNDdlNDM4MjZkYjhhZDZmZTk2ZjRjMTNjOGIyODBhYWM2" } ], "infoArticle" : false, "name" : "WAGO-I/O-CHECK; USB-Set", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "WAGO-I/O-CHECK", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/wago-i-o-check/p/759-302_000-923", "uuid" : "wagoProductCatalog/Online/759-302/000-923" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-2283/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Function: “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies communication between products from different manufacturers. The PFC200 Controller (2nd generation) can be operated as a BACnet building controller and supports the B-BC device profile with all major BACnet objects and interoperability building blocks (BIBBs). The device communicates via BACnet/IP and offers the functionality of a BACnet Client and BACnet Server. To use BACnet/IP, it is necessary to equip the device with a license. The BACnet network is configured using the WAGO BACnet Configurator and the Engineering Software. Benefits: Use the device as a BACnet Building Controller (B-BC) Control and detect distributed I/O signals from WAGO BACnet/IP Couplers via BACnet Fieldbus Protocol Data exchange with other BACnet Devices as a BACnet Client or Server Use: The license is registered in WAGO Upload and loaded onto a device. No other installation steps are required. Technical Data: See “Protocol Implementation Conformance Statement” (PICS) Compatible Controllers: 750-8210 PFC200; G2; 4ETH 750-8211 PFC200; G2; 2ETH 2SFP 750-8212 PFC200; G2; 2ETH RS 750-8213 PFC200; G2; 2ETH CAN 750-8216 PFC200; G2; 2ETH RS CAN DPS 750-8217 PFC200; G2; 2ETH RS; 4G ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzk1fGltYWdlL2pwZWd8YUdaaUwyaGlPUzh4TXpJME9UVTNOell4TlRNNU1DOHhNakJmTWpRNU5UWTFNVjlFUlM1cWNHY3w1YzIzNGJiOTJhZTA2N2FlOGRkODQyYzNiZjczODFlNDUyNmY1MjU2YzdkZDNkYzg0ZDkxYzZhMTA0ODk5NWU5" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMTk2fGltYWdlL2pwZWd8YUdOakwyaGpNQzh4TXpJME9UVTNOelF4T0RjNE1pOHlNREJmTWpRNU5UWTFNVjlFUlM1cWNHY3w2ZDEwY2VhZjU2NWVlZDVmNGMzOGZmODhkZDYzNWE1YmNhMmJkMWVjMWExOWM1MThjNmJmMWJlOWMwMGVmZmQ3" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2495651-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODEzNHxpbWFnZS9qcGVnfGFHTmhMMmhqTXk4eE16STBPVFUzTnpNMU16STBOaTgwT0RCZk1qUTVOVFkxTVY5RVJTNXFjR2N8NDY4OWYxNTkxYzc2ZDVhODUxZDNmMGM1MGQ0OGQ3NmUyMDQyMTgyZjk0N2ExNGMwNmQ5YzM2ZDNjZjMwZTY0Yg" } ], "infoArticle" : false, "name" : "Runtime; BACnet; 300; M; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Runtime", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/runtime/p/2759-2283_211-1000", "uuid" : "wagoProductCatalog/Online/2759-2283/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-286/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Function: “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies communication between products from different manufacturers. The WAGO Touch Panel can be operated as a BACnet building controller and supports the B-BC device profile with all major BACnet objects and interoperability building blocks (BIBBs). The device communicates via BACnet/IP and offers the functionality of a BACnet Client and BACnet Server. To use BACnet/IP, it is necessary to equip the device with a license. The BACnet network is configured using the WAGO BACnet Configurator and the Engineering Software. Benefits: Use the device as a BACnet Building Controller (B-BC) Control and detect distributed I/O signals from WAGO BACnet/IP Couplers via BACnet Fieldbus Protocol Data exchange with other BACnet Devices as a BACnet Client or Server Use: The license is registered in WAGO Upload and loaded onto a device. No other installation steps are required. Technical Data: See “Protocol Implementation Conformance Statement” (PICS) Compatible Touch Panels: 762-43xx/8000-002; Touch Panel 600 Standard Line; PIO 3 hardware configuration 762-53xx/8000-002; Touch Panel 600 Advanced Line; PIO 3 hardware configuration 762-63xx/8000-002; Touch Panel 600 Marine Line; PIO 3 hardware configuration xx is a wildcard; the license applies to all Touch Panel sizes. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2495652-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNjYxfGltYWdlL2pwZWd8YUdZd0wyaGtNaTh4TXpJME9UVXpNRGsxTXpjMU9DOHhNakJmTWpRNU5UWTFNbDlFUlM1cWNHY3xkNDI4ZTY3ODRlYjczZjYxZDEwN2MxMTU2NTZjNGQ2ZmMzMzJhZWU0MGZkY2UyOTU0YTlmZTg5MTA1NTU1Y2Jm" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2495652-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMTE4fGltYWdlL2pwZWd8YUdNd0wyaGtPUzh4TXpJME9UVXpNRGMxTnpFMU1DOHlNREJmTWpRNU5UWTFNbDlFUlM1cWNHY3xmZmU4NDc5NDkzMmI0NDIwOGIzZDM2ZGNiMzFjYmI2Y2M2MWU1OGM5NDlmMzQxMWY0M2ViMTNmYWNlY2U2NGIw" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2495652-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDU4OHxpbWFnZS9qcGVnfGFHSmxMMmhrWXk4eE16STBPVFV6TURZNU1UWXhOQzgwT0RCZk1qUTVOVFkxTWw5RVJTNXFjR2N8ZTQwZjcyZWMwYTg5NzcxOTljNmFjMDVmYjQzNzQxZTY5MDc1MWEyZDZlYmViMzliNzlkNjg2NjYzZDJlNmRjMA" } ], "infoArticle" : false, "name" : "Runtime; BACnet; 600; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Runtime", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/runtime/p/2759-286_211-1000", "uuid" : "wagoProductCatalog/Online/2759-286/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-293/211-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " Function: Communication according to the IEC 61850 Protocol can be conveniently parameterized with a configurator integrated into the e!COCKPIT Software. The configurator sets up IEC 60870 objects while configuring data exchange to the PLC application or I/O modules. Import and export functions in CSV format allow configured data to be transmitted to other engineering tools. With this license, the IEC 60870-5-101, -103 and -104 Protocols can be activated on the master. This permits the creation of gateways that convert one protocol into another, e.g., allowing protection devices to be read out via IEC 60870-5-103 and data to be transmitted to the network control system via IEC 60870-5-104. IEC 60870-101/-104 Information Objects can be used to monitor the direction of single, double and step messages – bit patterns, counter values, as well as normalized, scaled and floating-point measurement values can also be used. All information objects can be received with or without a time stamp. This also applies to information objects in the control direction. The IEC 60870-5 Master can support connections to up to 10 IEC 60870-5 Slave Devices. Your Benefits: Use the controller as a telecontrol master to read data from IEC-60870-5-101/-104 Field Devices or IEC-60870-5-103 Protection Devices (slaves) and process it locally in the controller. Create a gateway application to use this master function to forward read data to a higher-level control system or cloud. This may require additional software licenses, such as the WAGO IEC 60870 Slave, DNP 3 Slave, Sparkplug or WAGO Cloud. Uses: Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the controller. No other installation steps are required. Technical Data: See Section “Functionality of the WAGO Protocol Library according to IEC 60870-5-101, and -104” in Product Manual “Configuring the IEC 60870 Protocol with the Telecontrol Configurator and e!COCKPIT.” ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-5279193-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNzU1fGltYWdlL2pwZWd8YURObEwyZzRNaTh4TXpjNU9EUXpPRFl6TXpVd01pOHhNakJmTlRJM09URTVNMTlFUlM1cWNHY3w4MGUxYjI4NjcwYjRjZTVkNTkxOTAyZTc0NTVlNTFlZjZkNmQ3MGVmNzI2MmFmOTU3ZmE5OTQzNTRkZGY5MDE5" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-5279193-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMTU5fGltYWdlL2pwZWd8YURCbUwyZzRPUzh4TXpjNU9EUXpPRFF6TmpnNU5DOHlNREJmTlRJM09URTVNMTlFUlM1cWNHY3w3NWJiMDY5ZjgyYzQyZGRlNzBkOTIyMjlhYWMzYjQyYjdmYjEwMzQ4MzU5ZTM4MmFiNjQ0NjFiNTkyYWRhY2Fm" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-5279193-DE.jpg?context=bWFzdGVyfGltYWdlc3wxNDIzMHxpbWFnZS9qcGVnfGFEQmpMMmc0WXk4eE16YzVPRFF6T0RNM01UTTFPQzgwT0RCZk5USTNPVEU1TTE5RVJTNXFjR2N8ZDJkNGRkNTU2OTIxMzJiOWMxYjljM2ZmNmRjNmU1NDUwYTRjMjljOTI2Nzk4MWU0OGYzNDg1ODA0YmM3YTg2MQ" } ], "infoArticle" : false, "name" : "Runtime; IEC60870 Master; M; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Runtime", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/runtime/p/2759-293_211-1000", "uuid" : "wagoProductCatalog/Online/2759-293/211-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-2102/271-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "WAGO Visualization Lighting Management provides an optional independent user interface for operating and monitoring WAGO Lighting Management (2759-0204/0261-1000). Whether on a desktop PC, touch panel, tablet or smartphone, the entire lighting system can be operated clearly and conveniently during ongoing operation via a modern HTML 5 web user interface. Through the visualization of operating data, the user is informed at all times about the current operating status of the entire lighting system and can intervene manually if necessary. Simultaneously accessing several lighting management controllers from the visualization is also possible. Depending on the number of controllers to be operated, three different license types are available. The visualization can be easily adapted to individual requirements. In addition to language and color settings, HMI devices, users, rooms and custom profiles in particular can be created and managed. Profiles make it possible to associate an individual user interface with each HMI device or user. Visualization – S; 1 controller; Item No.: 2759-2101/271-1000 Visualization – M; up to 3 controllers; Item No.: 2759-2102/271-1000 Visualization – L; up to 10 controllers; Item No.: 2759-2103/271-1000 Compatible Controllers/Touch Panels: Controller PFC200; 2nd Generation; Item No.: 750-8212 Touch Panel 600 Advanced Line; PIO3; Alternative: Touch Panel with capacitive touchscreen as basic unit: 762-53xx/8000-0002 ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNzY5fGltYWdlL2pwZWd8YUdWa0wyZ3lPQzh4TXpJME9UY3lNek16TkRZNE5pOHhNakJmTWpZeU9ETTFPVjlFUlM1cWNHY3wwNDk4M2Y3MGQxNTBlNDllNDExMWUwN2JiOGMyMmMwZWM4ZGZhMTRlNDMzYzVlMzhmMGNmNzdhZTgwM2U5NDNl" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODgyfGltYWdlL2pwZWd8YUdKa0wyZ3laaTh4TXpJME9UY3lNekV6T0RBM09DOHlNREJmTWpZeU9ETTFPVjlFUlM1cWNHY3xlMDMwZTlmZmNjMWFhODY3NWY4ZTU3MWEzOTI4NDg2MGQ5ZDY1NGFjMTgwOGVlODAyNDA3ZGE4MDQ0YjJmMjNj" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2628359-DE.jpg?context=bWFzdGVyfGltYWdlc3wyNDUzNHxpbWFnZS9qcGVnfGFHSmlMMmd6TWk4eE16STBPVGN5TXpBM01qVTBNaTgwT0RCZk1qWXlPRE0xT1Y5RVJTNXFjR2N8NTdlMWQ4M2U0YWZlNGQ1MmU4NTY4YmRiNjk5OTllZjVhMjQ2NzE0Y2RjODBmMWIzY2YzZDgyN2I2OTVjM2ZkOQ" } ], "infoArticle" : false, "name" : "Visualization Lighting Management; M; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Visualization Lighting Management", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/visualization-lighting-management/p/2759-2102_271-1000", "uuid" : "wagoProductCatalog/Online/2759-2102/271-1000" }, { "announced" : false, "cancelled" : false, "categoryNames" : [ "Software" ], "code" : "2759-207/271-1000", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : "License for the visualization of dashboards and diagrams in responsive design", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-2809457-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODAxfGltYWdlL2pwZWd8YUdFekwyaG1PUzh4TXpJMU1EQXhPRE0zTnpjMU9DOHhNakJmTWpnd09UUTFOMTlFUlM1cWNHY3w5Y2RlYTYxMDM1MGM0MWU5ODIzZWJiZTI5MDcyNzIzNzVhNWE2YWM2MjFiM2UwZDljMjlmZjg0ZjdlZWExMWY0" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-2809457-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDM0fGltYWdlL2pwZWd8YUdVMkwyaG1NaTh4TXpJMU1EQXhPREU0TVRFMU1DOHlNREJmTWpnd09UUTFOMTlFUlM1cWNHY3w5NzUyYjE2MWVmMGZlODhkNDY1NmFjOTA3MDc2ZDc4NWMwMTk2NzVjZWE4MTczZDM1NGY1YzViZmZjNDE2NGRj" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-2809457-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMzc2M3xpbWFnZS9qcGVnfGFESTFMMmhtTWk4eE16STFNREF4T0RFeE5UWXhOQzgwT0RCZk1qZ3dPVFExTjE5RVJTNXFjR2N8Zjk4YzZjODFmMTI0NDc4NTE5NzM0NGM1YjEzNDBlZGQ0ZDA2NjVjZjIwOTNjZTJjMTI5MzljOGRiZDc5ZDNlYQ" } ], "infoArticle" : false, "name" : "Visualization Energy Data Management; Single License; Online activation", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : true, "sampleProduct" : false, "shortName" : "Visualization Energy Data Management", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/visualization-energy-data-management/p/2759-207_271-1000", "uuid" : "wagoProductCatalog/Online/2759-207/271-1000" }, { "announced" : false, "cancelled" : true, "categoryNames" : [ "Software" ], "code" : "2759-101/1110-2020", "containsDownloads" : true, "customerArticleNumbers" : [ ], "customerSpecific" : false, "dataType" : "Product", "description" : " WAGO Automation Software e!COCKPIT for faster machine and system startup: WAGO's new engineering software shortens development time for automation projects while impressing with a modern and clearly laid out user interface. At the software’s core is CODESYS V3 for simple and versatile creation of applications. Ensuring a project’s long-term viability through sustainable cost savings hinges on the user’s ability to quickly adapt to new software that offers a high degree of reusability. WAGO set out to fulfill these exact requirements by developing its own engineering software: e!COCKPIT. This integrated development environment supports every automation task, from hardware configuration, programming, simulation and visualization, to commissioning – all in one software package. Use the programming tool to handle all important automation tasks, and implement especially complex projects quickly and easily. Configuration and Parameterization The integrated e!COCKPIT configurators provide state-of-the-art operating tools and workspaces, such as: Graphical network topology: Complex relationships between network devices and their current states can be identified easily and intuitively. Drag & drop: Simplifies device interaction. Copy & paste: Individual devices or whole network branches can be duplicated quickly. Batch processing: Parameter values are set simultaneously for several devices. Programming e!COCKPIT offers multiple software development options: IEC 61131-3 PLC programming languages: Structured Text (ST), Ladder Diagram (LD), Function Block Diagram (FBD), Instruction List (IL), Sequential Function Chart (SFC), Continuous Function Chart (CFC) For flexibility, all programming languages can be combined with one another. Created programs can be easily debugged on the engineering PC via simulation. New paradigms such as object-oriented programming are included. Visualization Advanced user interfaces for machine operation and monitoring are standard. Today, HMI-based design is a critical factor that influences the purchase of an entire automation line. e!COCKPIT employs Drag & Drop to streamline the design of modern user interfaces. The integrated visualization editor provides: Access to IEC program variables Closed simulation of HMI and PLC programs on the engineering PC Guaranteed language independence via Unicode character set Current standards such as HTML 5 and CSS Diagnostics Being acutely aware of the automation network’s current status is vital for rapid fault localization and debugging – be it during development in the office or directly on the machine during commissioning. e!COCKPIT provides comprehensive diagnostic capabilities: Individual views, for example, always display the controllers’ status information both graphically and in tabular form. To keep the project on time, error messages are transmitted directly and clearly. The structured wiring test function systematically identifies wiring errors. ", "hasCounterparts" : false, "hasFollowUpProduct" : false, "images" : [ { "format" : "120", "imageType" : "PRIMARY", "url" : "/medias/120-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxODc2fGltYWdlL2pwZWd8YUROaUwyZzBOQzh4TWpJMk5UTTNOekl6TkRrM05DOHhNakJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDE4ZGRhNWM3YjI4NjI3ZjI0ZGQzNTZmYTdkNTY2Y2JlNDhmYzNiY2E3ODc3MTZmNDFkMDJhMTAyZDc0MTg0MzE" }, { "format" : "200", "imageType" : "PRIMARY", "url" : "/medias/200-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxMDU3fGltYWdlL2pwZWd8YURCaUwyZzBZaTh4TWpJMk5UTTNOekF6T0RNMk5pOHlNREJmTURJd01EQXdNV013TURBeVpqQm1NekF3TURFd01HSTJYMFJGTG1wd1p3fDgxY2YxMzU3NTBmMGRiYTE5YjdmYmMzOTRhNjRhMDlhMWYzODc3YThhZmRjODlmZDYwMzVjZGU2MDFhMTA2YWM" }, { "format" : "480", "imageType" : "PRIMARY", "url" : "/medias/480-0200001c0002f0f3000100b6-DE.jpg?context=bWFzdGVyfGltYWdlc3wxOTQxOHxpbWFnZS9qcGVnfGFHSTFMMmc1TlM4eE1qSTJOVE0zTmprM01qZ3pNQzgwT0RCZk1ESXdNREF3TVdNd01EQXlaakJtTXpBd01ERXdNR0kyWDBSRkxtcHdad3xjYmQyNGFkNTE0MmMyMjliMjcxY2VhNjBjMzEwYzUwZmUzY2VkODU0YThiYWExNmJjOTlkMjJkZjk3MTI2MzNk" } ], "infoArticle" : false, "name" : "e!COCKPIT software; license (20 users)", "newProduct" : false, "numberContentUnits" : 1.0, "numberPackageUnits" : 1.0, "purchasable" : false, "sampleProduct" : false, "shortName" : "e!COCKPIT software", "showFamily" : false, "stockArticle" : false, "unit" : { "name" : "Piece", "namePlural" : "Pieces" }, "url" : "/software/e-cockpit-software/p/2759-101_1110-2020", "uuid" : "wagoProductCatalog/Online/2759-101/1110-2020" } ], "sorts" : [ { "code" : "relevance", "name" : "Popularity", "resultTypes" : [ "product" ], "selected" : true }, { "code" : "code-asc", "name" : "Item No. (ascending)", "resultTypes" : [ "product" ], "selected" : false }, { "code" : "code-desc", "name" : "Item No. (descending)", "resultTypes" : [ "product" ], "selected" : false } ] }